●Department of Water & Sanitation — National water status updates●FPASA — Fire Protection Association of Southern Africa●ASIB — Automatic Sprinkler Inspection Bureau●News24: South Africa water crisis coverage●SABC News — Water and fire safety reporting●Reuters — Global water security news●BBC News — Wildfires and fire hazard updates●IOL — Drought, water shedding and supply news
Videx Storage Tanks

Product Guides

How Water Towers Work: Elevated Tanks and Gravity-Fed Pressure

Elevated steel water tank on a modular tower against a clear sky

How elevated tanks use height to create water pressure, what a water tower includes, and what to plan for when specifying one.

A water tower is a storage tank raised on a structure so that gravity, not a pump, pushes water through the pipes. The higher the water sits above the point of use, the more pressure it delivers: roughly 1 bar for every 10 m of height. A pump fills the tank at a steady rate, and the tower then supplies water at a stable pressure, even during peak demand or a power outage.

Water towers are common on farms, mines, estates, rural community schemes and industrial sites across South Africa. In summer, when demand peaks and mains pressure can drop, an elevated tank keeps water flowing to taps, troughs and processes without relying on a pump running every minute.

This guide explains how gravity-fed pressure works, what an elevated steel tank includes, and what to plan for when specifying one.

Key takeaways

  • Water pressure from a tower comes from height: about 1 bar (roughly 100 kPa) for every 10 m between the water level and the outlet.
  • The tower acts as a buffer. Pumps fill it steadily; gravity supplies peaks in demand.
  • Gravity supply keeps working during load shedding and pump failures, for as long as water remains in the tank.
  • Elevated tanks are engineered structures. Foundations, wind loading and steelwork must be designed by a professional engineer.
  • Taller is not always better. Height should match the pressure the system needs.

How gravity creates water pressure

Water is heavy. A column of water pushes down on everything below it, and that weight is felt as pressure at the bottom. This is called static head.

The rule of thumb is simple:

Every 10 m of height between the water level and the outlet gives about 1 bar of pressure.

Height of water level above outlet Approximate static pressure
5 m 0.5 bar (about 50 kPa)
10 m 1 bar (about 100 kPa)
15 m 1.5 bar (about 150 kPa)
20 m 2 bar (about 200 kPa)

Actual pressure at a tap is lower than static pressure once water flows, because pipes, bends and valves create friction losses. Long pipe runs and small pipe diameters increase these losses, so pipe sizing matters as much as tower height.

Why use a water tower instead of a pump?

Stable pressure

A pump switching on and off can cause pressure to rise and fall. A tower delivers steady pressure set by its height, which is gentler on pipes and fittings.

Buffer storage for peak demand

Demand on most sites is uneven: high in the morning, at shift changes or during irrigation, and low overnight. A tower lets a smaller pump fill the tank steadily over the day while the stored water meets the peaks.

Supply during power cuts

Because gravity does the work, an elevated tank keeps supplying water during load shedding or a pump breakdown, until the stored volume runs out. For many farms, schools and community schemes, that reserve is the main reason to build a tower.

Lower running costs

Pumps can run at their most efficient point to fill the tank, instead of starting and stopping to meet every small demand.

What an elevated steel tank includes

A complete elevated water tank system usually includes:

  1. Foundation: reinforced concrete bases designed for the full weight of the structure and water, plus wind loads.
  2. Tower structure: a steel frame with bracing, designed to carry the tank safely in all expected conditions.
  3. Tank: a steel tank sized to the storage the site needs.
  4. Inlet and level control: a rising main from the pump, with a ball valve or level switch to stop the tank overflowing.
  5. Outlet: the gravity supply pipe to the site, with an isolation valve.
  6. Overflow and drain: to discharge excess water safely and allow the tank to be emptied for maintenance.
  7. Access: ladders, platforms and hatches with safe access for inspection.

Videx elevated water towers are structurally engineered by a professionally registered (PR) engineer to SANS 10162, and each tower comes with General Arrangement (GA) drawings, a full civil design and a site-specific foundation bending schedule.

What to plan for when specifying a water tower

Pressure and height

Start with the pressure needed at the furthest or highest point of use, add an allowance for friction losses, and work back to the height of the tank. The ground level of the tower site compared with the points of use also matters. A tower on a rise needs less structure for the same pressure.

Storage volume

Size the tank to cover peak demand plus the reserve you want during power cuts or pump downtime. Our guide on how to size a water storage tank explains how to estimate daily demand and reserve.

Ground conditions and foundations

An elevated tank puts large, concentrated loads on its foundations. A geotechnical assessment of the soil helps the engineer design the right bases. Never place a tower on fill or unassessed ground.

Wind and structural loads

Tall structures carrying heavy loads must be designed for wind. This is one reason elevated tanks are always engineered structures rather than off-the-shelf stands.

Approvals

Many municipalities treat elevated tanks as building work. The City of Cape Town's guidelines for alternative water installations, for example, list tanks on supporting structures more than 1 m above the surrounding ground among those that need building plan approval. Check your municipality's requirements early in the project.

Access and maintenance

Plan safe access for inspection and cleaning from the start, including ladders with safety cages or fall protection, platforms and lockable hatches.

Where elevated water tanks are used

  • Municipal and community supply: gravity-fed distribution to towns, villages and district schemes. See our municipal reservoirs page.
  • Mining camps and industrial sites: reliable pressure for process water, wash-down and accommodation.
  • Agricultural estates and farms: gravity supply for irrigation, livestock and homesteads.
  • Rural communities: water that keeps flowing when the power goes off.
  • Fire protection pressure: gravity supply for sprinkler and hydrant rings where the fire design allows it.

Water towers vs ground-level reservoirs

Ground-level reservoirs store larger volumes more economically, but need pumps to deliver pressure. Elevated tanks store less but deliver pressure without power. Many schemes use both: a large ground-level water reservoir for bulk storage, with a pump lifting water to a tower that provides pressure to the network.

Frequently asked questions

How high should a water tower be?

High enough to give the pressure needed at the furthest point of use after friction losses. As a guide, every 10 m of height gives about 1 bar of static pressure. An engineer will confirm the height from your site levels and pipe layout.

How much water does a water tower hold?

It depends on the site's demand and the reserve needed during power or pump outages. Tank capacity and tower height are designed together, because the structure must carry the full weight of the stored water.

Does a water tower need a pump?

A pump is usually needed to fill the tank, unless it is fed from a higher source. Once filled, the tower supplies water by gravity without pumping.

What standard are steel water towers designed to?

Videx elevated water towers are structurally designed to SANS 10162 by a professionally registered engineer, with GA drawings, civil design and a foundation bending schedule.

This article provides general guidance only. Elevated water tanks are engineered structures, and height, capacity and foundations must be designed by a qualified, professionally registered engineer.

About this article

Written by the engineering team at Videx Storage Tanks, a South African manufacturer of sectional, cylindrical and elevated steel water storage tanks based in Wadeville, Gauteng, with a branch in Bellville, Cape Town. Videx has more than 40 years of experience and more than 500 completed projects, and is ISO 9001:2015 certified.

Planning a gravity-fed water supply? Speak to a Videx engineer about tower height, capacity and foundations.

Back to all articles

Proven on site

Latest Projects

Real Videx installations across South Africa.

  • Southgate Mall Fire-Water Tank189 kL
  • Turffontein Fire Protection923 kL
  • VOX Fire Heidelberg1,008 kL
  • Leroy Merlin Cornubia631 kL
View case studies